This means a much smaller transformer should work other than for internal impedance. All systems are available with a suite of image enhancement tools that make it more convenient to examine areas of concern, and feature autoSoft, the industry’s most stable operating system. With a range of tunnel sizes, conveyor speeds, capacities and footprints, there is an Autoclear X-ray screening solution for every application. If this machine is used to take regular medical x-rays, then I doubt there would be a duty cycle anything close to 1/10. Autoclear X-ray inspection systems are user-friendly and feature-rich. A different question would be whether the transformer internal impedance was sufficiently low. This would never overheat the transformer. Further suppose the duty cycle was 1/10 meaning once every 1 second there was 0.1 second load. Certainly the specifications are not very useful without a prior knowledge.īut let us assume 345 A input for 0.1 second and its 82.8 KVA value, and you have chosen a 50 KVA transformer. Our x-ray technology for the food industry can also simultaneously perform numerous inline quality checks such as mass measurement, fill level or weight verification, component count, package integrity, as well as identify missing or damaged product. On the other hand if the 30 or 37.5 KW represents either input power or output power the 345 might not be out of line as a current. Eagle’s world-class x ray machines for food processing inspection provide unsurpassed foreign body contamination detection for metal, stone, glass shards, high density plastics or rubber and even bone fragments.
For a resistive load 345 A at 240 V calculates to 82.8 KVA, and KW. Is the 345 A a power supply inrush current when you connect power, or is this the current during the 0.1 second on time.
Xray machine generator#
The generator types utilized in X-ray machines are of three types, including high frequency, constant potential, and single phase. It serves as the central control system through which the x-ray generator current flows into the x-ray tube. You can do other Internet searching.Ĭontinuing to your problem. The x-ray generator is the component that produces an x-ray when an electrical current is employed. If I read them correctly they may be referring to near continous duty. One reference is for a unit near your size. For higher energy x-rays the voltage will be higher.
The X-ray generator should be placed in a ventilated and dry place, avoid humidity, high temperature, corrosion and other environments, so as not to reduce the insulation performance, cause equipment. That is about the lowest voltage at which x-rays are generate. After the inspection operation is completed, the dirt and dust on the surface of the machine must be wiped to keep the equipment tidy 2. We know the x-ray machine has to produce an output voltage in excess of 10,000 V. The peak ampere rating is 345 A whatever this means. I can not answer your question and I have no experience with the device.įirst, call the x-ray machine manufacturer and ask what size transformer should be used and its internal impedance.